Heatpump Defrost

Heatpump Defrost


Here’s a transient introduction to heatpump defrost.

In window heatpump or break up heatpump unit, there may be often a perform known as heatpump defrost mode the place the unit will routinely defrost the frost that has constructed up within the out of doors coils throughout heating operation.

The defrosting of the out of doors unit have to be finished in any other case it is going to have an effect on the heating efficiency of the unit.




Heatpump unit often has cool mode which is used throughout summer time and warmth mode which is used in the course of the winter season. A tool known as reversing valve or 4 Method Valve is used to reverse the movement of the refrigerant to find out the mode that’s in operation.

Throughout cooling mode the refrigerant will movement within the path that causes the unit indoor to perform as an evaporator therefore giving cool air into the area.

In heating mode, the reversing valve is activated that causes the movement of the refrigerant to reverse inflicting the unit indoor to perform as a condenser and the out of doors as an evaporator. This causes the indoor to be heated up.

Heatpump Defrost Operation

Throughout winter season, the unit can be required to offer heating to the room, therefore you will want to function the heatpump in HEAT mode. Throughout this time, the reversing valve can be activated.

Because the out of doors unit temperature continues to drop as a result of extraction of warmth from it and the encompassing, frost begins to construct up within the out of doors coils. Defrosting mode will then kick in when the situations to defrost are met.

A typical reversing valve or 4 Method Valve

In some fashions, auxiliary electrical heater is built-in to offer heating throughout this time. On this case, the indoor fan will proceed to function and supply heating to the occupants. You’ll need to test whether or not your unit is put in with this aux heater.

Circumstances To Go Into Defrost

Relying on producers, the situations of going into defrosting are managed by the microcomputer of the unit. A temperature sensor is positioned on the out of doors coil of the out of doors unit and suggestions to the microcomputer.

A typical situations embrace the followings which can differs from producers to producers. A timer will begin when the sensor sense a temperature of two°C to 4°C or under.

  • First Hour 

    After about half an hour of HEAT operation with sensor temperature under 2°C to 4°C, if the sensor temperature drops under -9°C, the defost mode will begin. It’s going to proceed to run for a interval of about 10 to fifteen minutes or till the sensor sense a temperature of larger than 9°C. Throughout this time, the frost can be melted by the warmth extracted from the indoor. After that, the unit will routinely cease the defrosting and goes again to heating mode to proceed offering warmth to the room.

  • First to Second Hour

    After the primary hour of HEAT operation with sensor temperature under 2°C to 4°C , it’s assumed that some frost will need to have built-up on the out of doors unit therefore the unit will go into heatpump defrost mode if the sensor sense a temperature of -5°C or under. Throughout this time, the frost can be melted by the warmth extracted from the indoor. After that, the unit will routinely cease the defrosting and goes again to heating mode.

  • Second Hour Onwards

    After the second hour of HEAT operation with sensor temperature under 2°C to 4°C, extra frost would have constructed up on the out of doors unit. Therefore the unit will go into defrost mode if the sensor temperature is -3°C or under. Throughout this time, the frost can be melted by the warmth extracted from the indoor. After that, the unit will routinely cease the defrosting and goes again to heating mode.


Again To Heatpump Defrost House Web page 

Whether you require installation, repair, or maintenance, our technicians will assist you with top-quality service at any time of the day or night. Take comfort in knowing your indoor air quality is the best it can be with MOE heating & cooling services Ontario's solution for heating, air conditioning, and ventilation that’s cooler than the rest.
Contact us to schedule a visit. Our qualified team of technicians, are always ready to help you and guide you for heating and cooling issues. Weather you want to replace an old furnace or install a brand new air conditioner, we are here to help you. Our main office is at Kitchener but we can service most of Ontario's cities