R32 Refrigerant For HVAC Business

R32 Refrigerant For HVAC Business


R32 refrigerant is often known as difluoromethane and belongs to the HFC household of refrigerant. This gasoline is poised to switch the opposite gaseous resembling R-410A and R-407C as the popular gasoline because of its decrease International Warming Potential. Its chemical system is CH2F2.

On account of the Montreal Protocol 1987 to part out ozone depletion gaseous, the R-410A and R-407C are refrigerant blends which can be used to switch ozone depletion refrigerants resembling R22 as each of those gaseous have zero ODP(Ozone Depletion Potential). Difluoromethane constitutes a good portion in each of those gaseous therefore its availability out there shouldn’t be a difficulty.




International Warming Potential & Ozone Depletion Potential 

The invention of the greenhouse results of refrigerants which can be used to switch ozone depletion gaseous have prompted the gamers within the HVAC business to search for higher refrigerants. The worldwide warming is a significant issue that’s plaguing the world and the general temperature of the earth has been rising.

This prompted many producers to start to plan phasing out refrigerants resembling R-407C, R-410A, R-134A and change them with decrease GWP resembling R32. It has a boiling level of -51°C.

R32 makes use of 78% lesser refrigerant to function in comparison with R-410A and most newer merchandise in Japan have been phasing on this refrigerant since 2013.

This gasoline is categorized below flammability stage A2( ISO 817:2014) therefore care needs to be taken when utilizing this gasoline. It is extremely near R-410A when it comes to working circumstances and efficiency. Different refrigerants which can be being thought-about to be used sooner or later are R1234yf and R1234ze.

See the desk under that compares the GWP and ODP of varied refrigerants primarily based on IPCC(Worldwide Panel On Local weather Change) 2007 Fourth Evaluation Report on Local weather Change over a 100-years of time horizon.

Take be aware that carbon dioxide has a GWP of 1 and ODP of 0. 

R11 refrigerant has a GWP of 4750 and ODP of 1.

The manufacturing of R22 had been phased out in 2015.

It’s reported that if the plan to phased out ODP merchandise are adhered to, the ozone layer will return to its situation as within the Eighties. That is excellent news and all effort needs to be taken to part out non-zero ODP inflicting merchandise.

RefrigerantInternational Warming PotentialOzone Depletion Potential
R1147501
R2218100.055
R410A20880
R407C17700
R134A14300
R326750
C0210R1234yf40

R32 and R410A Saturation Steam Stress Comparability

Temperature/&degCR32R410A
-200.30 MPa0.30 MPa
00.71 MPa0.70 MPa
201.37 MPa1.35 MPa
402.38 MPa2.32 MPa
603.84 MPa3.73 MPa
654.29 MPa4.17 MPa
  • The comparability above reveals that each refrigerant has related working temperature.
  • The identical piping as R410a can be utilized.
  • Each refrigerants are utilizing artificial oil (ether).
  • A lot of the instruments used for R410a may also be used such because the gauge manifold, cost hose, cost valve, electrical leak detector, vacuum pump adapter, vacuum pump, refrigerant restoration tools and digital weight scales. Nonetheless, the refrigerant restoration cylinder can’t be shared.

Professional and Cons of R32 In comparison with R-410A

The Advantages

  1. Zero ODP
  2. One third of R-410A GWP.
  3. Required much less cost because it has a 20% larger volumetric capability.
  4. Related saturated stress therefore improvement is less complicated.
  5. Larger vital temperature therefore larger COP.
  6. Decrease density therefore the quantity of cost required is smaller.
  7. Single element of gasoline, due to this fact it’s simpler to be produced and managed.

The Disadvantages

  1. Toxicity stage barely larger and extra precaution is required to make use of it.
  2. Larger discharge temperature will trigger oil degradation within the compressor which can injury a number of the elements in it. Design consideration is required to make sure the discharge temperature is restricted to a suitable stage.

This refrigerant is certainly extra environmental pleasant and its use needs to be inspired in any respect ranges starting with the governing authorities. It’s a good alternative refrigerant for R22 and R410A.




Whether you require installation, repair, or maintenance, our technicians will assist you with top-quality service at any time of the day or night. Take comfort in knowing your indoor air quality is the best it can be with MOE heating & cooling services Ontario's solution for heating, air conditioning, and ventilation that’s cooler than the rest.
Contact us to schedule a visit. Our qualified team of technicians, are always ready to help you and guide you for heating and cooling issues. Weather you want to replace an old furnace or install a brand new air conditioner, we are here to help you. Our main office is at Kitchener but we can service most of Ontario's cities


Supply hyperlink

Add Comment

Your email address will not be published. Required fields are marked *